ICEA 2000V Flat&Round Type W Portable Power Mining Cable 4 0 AWG

Mining Trailing Cable

Product Categories

Heavy-duty rubber cables for mining, port cranes, submersible pumps, EV charging, elevators and marine duty. Pick a family to filter the range.

Mining Trailing Cable

TEBAOFLEX mining trailing cables connect shovels, draglines, continuous miners, shuttle cars and LHD loaders to the mine power system while the machine moves. The range spans two families: ICEA types such as SHD-GC, G-GC and Type W, rated 600/2000 V to 25 kV in AWG/kcmil sizes with grounding and ground-check conductors where the type requires them, and VDE types such as NSSHCGEÖU, NSHTOEU and (N)TSCGEWÖU, rated 0.6/1 kV to 20/35 kV in mm² with Class 5 conductors.

Selection Guide

Mining Trailing Cable Selection Guide

Model comparison, operating conditions and RFQ checklist.

Product Advantages

What sets TEBAOFLEX Mining Trailing Cable apart in service.

ICEA and VDE Families

North American ICEA types in AWG/kcmil and European DIN VDE 0250 types in mm², so the cable matches the rules the machine was designed around.

Earth Monitoring Conductors

Type G-GC and SHD-GC carry two grounds and one yellow-insulated ground-check conductor; NSSHCGEÖU(V) has concentric monitoring conductors around its control cores.

Low to Medium Voltage

600/2000 V Type W and G-GC, 0.6/1 kV NSSHCGEÖU and NSHTOEU, 2–25 kV SHD-GC and medium-voltage VDE types from 3.6/6 kV to 20/35 kV.

Flexible Tinned Copper

Stranded tinned copper to ASTM B-172 on Type G-GC and Type W, Class 5 flexible copper on VDE types, for cables that are dragged, reeled and flexed.

Feeder and Hoist Cables Too

Type MP-GC and (N)3GHSSYCY feeders, NTMTWOEU hoist cable, DLO leads and P1209 monitoring cable are listed alongside the trailing types.

CPE, PCP and LSZH Sheaths

CPE jackets on Type G-GC and Type W, CPE or TPU on SHD-GC, PCP 5GM5 on NSSHCGEÖU and NSHTOEU, and halogen-free sheaths on (N)3GHSSHCH for tunnels.

Technical Specifications

Capabilities across the Mining Trailing Cable range; each product page lists the exact construction, rating and reference standard.

SpecificationAvailable options
Product typesICEA trailing types (SHD-GC, G-GC, W); VDE trailing and reeling types (NSSHCGEÖU, NSHTOEU, (N)TSCGEWÖU family, (N)TMCGETMPU); also listed: feeder, hoist, DLO and signal cables (MP-GC, (N)3GHSSYCY, NTMTWOEU, P1209, LiYCY)
Rated voltage600/2000 V (Type W, G-GC); 2–25 kV (SHD-GC); 5–15 kV (MP-GC feeder); 0.6/1 kV to 20/35 kV U0/U (VDE types); 0.69/1.15 kV (TRM-J, TRMC-J)
ConductorStranded tinned copper to ASTM B-172 (Type W, G-GC); bare or tinned copper (SHD-GC); Class 5 flexible tinned or bare copper to IEC 60228 / DIN VDE 0295 (VDE types)
Cross-sectionAWG/kcmil on ICEA types, e.g. 4/0 AWG Type W and 535 kcmil DLO; mm² on VDE types, e.g. 3×25/16 to 3×150/70 (NSSHCGEÖU(V)) and 4×16 to 4×95 (NSHTOEU)
InsulationEPR (G-GC, Type W, VDE types to 3GI3); EPDM (SHD-GC, some VDE medium-voltage types); XLPE (MP-GC XLPE/PVC version); flame-retardant XLPO (125 °C DLO)
SheathCPE (G-GC, Type W, MP-GC EPR/CPE); CPE or TPU (SHD-GC); PCP or synthetic rubber 5GM5/5GM3 (VDE types); TPU ((N)TMCGETMPU, (N)TMCGCW11Y); halogen-free ((N)3GHSSHCH); PVC ((N)3GHSSYCY, P1209)
Grounding and monitoringTwo grounds plus one insulated ground-check conductor (SHD-GC, G-GC, MP-GC); no bare grounds (Type W); ground-check conductor ((N)TMCGETMPU); concentric copper/steel earth with monitoring conductors (NSSHCGEÖU); split or concentric earth with optional pilot cores (NTSCGECWOEU)
ReinforcementPolyester or polyamide anti-torsion braid (NSHTOEU, R-(N)TSCGEWÖU); copper–steel braid (NSSHCGEÖU(V), NSSHCGEÖU(Z)); optional polyester braid (Type W); galvanised steel wire braid (tunnel feeders)
Temperature90 °C maximum conductor temperature on most power types; -40 to +90 °C (Type W); fixed -40 to +80 °C and flexible -25 to +60/+80 °C on most VDE types; -55 to +125 °C (XLPO DLO)
Minimum bending radius6 × OD (Type W); 10 × OD (NSSHCGEÖU(V)); 6 × OD fixed and 10 × OD flexed ((N)TSCGECEWÖU); several VDE pages refer to DIN VDE 0298-3
Reference standardsICEA S-75-381, ICEA S-66-524, ICEA S-95-658, ASTM B-172, AAR RP-585/S-501; DIN VDE 0250 Parts 812, 813 and 814; DIN VDE 0298-3
DocumentsDatasheet, test report and certification documents for the exact model on request at RFQ stage

How to Choose Mining Trailing Cable

Four decisions specify the right cable the first time; send them with your RFQ and our engineers confirm the type designation.

1

ICEA or VDE

Follow the machine and site electrical rules: ICEA type letters with AWG/kcmil sizes, or DIN VDE 0250 type codes with U0/U ratings and mm² sections.

2

Voltage and Cores

Rated voltage, number and size of power cores, and the grounding, ground-check, pilot, control or fibre-optic cores the protection system needs.

3

Movement Type

Trailing, drum reeling, festoon, suspended or fixed duty; compare drum and sheave diameters, travel speed and tensile load with the product limits.

4

Site Environment

Permanent immersion only for submersible builds, the flexing temperature for mobile machines, and halogen-free, low-smoke sheaths where tunnels require them.

Industry Solutions

Cable packages engineered around the application, not just the cable.

Standards & Certifications

ISO 9001 quality management for cable production; ISO 14001 and ISO 45001 for sales and related management. UL and cUL (flexible cord), VDE (EN 50525-2-21), Korea KC, China MA and US MSHA approvals cover the certified types; CE is a third-party verification of conformity (VoC).

ISO 9001ISO 14001ISO 45001ULcULVDEKC (KTL)MAMSHACE VoC
UL Certificate of Compliance UL-US-2449012-4
UL Certification
VDE Marks Approval 40060056
VDE Certification
Korea KTL KC safety certification SU01346-25005
Korea KTL Certification
ISO 9001:2015 quality management system certificate 244-24-QI-17425-R0-S
ISO 9001 Quality Management

Manufacturing Process

From compound to shipment, the production steps and routine tests behind each cable length.

  1. 1

    Compound preparation

    EPR, CPE, PUR and silicone compounds are mixed and tested for hardness, tensile strength and elongation before use.

  2. 2

    Conductor stranding

    Tinned or bare copper is bunched and rope-stranded to Class 5/6 flexibility for trailing and reeling duty.

  3. 3

    Insulation extrusion

    Cores are extruded and continuously vulcanised; wall thickness and spark tests are recorded on every length.

  4. 4

    Core assembly and screening

    Cores, earth conductors, pilot and fibre-optic elements are laid up with the fillers and screens the type designation requires.

  5. 5

    Inner and outer sheathing

    Reinforced double-sheath constructions are extruded and cured for abrasion, oil and tear resistance.

  6. 6

    Routine electrical tests

    Conductor resistance, voltage withstand and insulation resistance tests at the levels set by the referenced standard.

  7. 7

    Mechanical and ageing tests

    Bending, tensile, hot-set, ozone and flame tests according to the referenced standard.

  8. 8

    Marking, packing and shipment

    Metre marking, drum packing and documentation for worldwide project delivery.

Cable Manufacturing Quality Control

Five-stage quality assurance from incoming copper to the packed drum.

  1. 01

    Raw Material Inspection

    Every batch of copper rod, rubber compound and reinforcing material is checked before it reaches the line.

    • Copper: conductor resistance, elongation and surface condition on incoming rod and drawn wire
    • EPR, CPE, PUR and silicone compounds: hardness, tensile strength, elongation and ageing samples from each mix
    ISO 9001IEC 60228
  2. 02

    Manufacturing Process Control

    Stranding, insulation extrusion, core assembly and sheathing run under recorded process parameters.

    • Class 5/6 stranding with lay length and tension monitored for trailing and reeling flexibility
    • Continuous-vulcanisation extrusion with wall thickness and spark tests logged on every length
    • Operators sign off each stage before the cable moves to the next machine
    ISO 9001Recorded parameters
  3. 03

    Electrical Testing

    Finished lengths go through the routine tests required by the referenced VDE, ICEA, IEC or NEK standard.

    • Conductor resistance and insulation resistance on every length
    • Voltage withstand test at the level set by the referenced standard
    • Screen and pilot-core continuity checks for mining and reeling constructions
    IEC 60502VDE 0250ICEA S-75-381
  4. 04

    Mechanical and Ageing Tests

    Samples from production are tested for the duty a mining, crane or submersible cable will actually see.

    • Tensile strength and elongation of insulation and sheath before and after ageing
    • Hot-set, ozone, oil-immersion and low-temperature bending tests
    • Constant-temperature water bath for insulation resistance of submersible constructions
    Hot-setOzoneOil immersionLow-temperature bending
  5. 05

    Flame Test and Final Inspection

    Before packing, the cable is checked against the order and the flame-performance requirement of its standard.

    • Single-cable vertical flame test to IEC 60332-1-2 where specified
    • Metre marking, printing, drum length and appearance inspection
    • Packing list with every shipment; test documents for the order confirmed at quotation
    IEC 60332-1-2Final inspection

Factory & Workshop Gallery

TEBAOFLEX CABLE, No.77 Wusongbang Road, Taicang, Suzhou.

Frequently Asked Questions

Quick answers about Mining Trailing Cable from our engineers.

01What is a mining trailing cable?

A mining trailing cable is a flexible, heavy-duty power cable that connects a moving mining machine, such as a shovel, dragline, continuous miner, shuttle car or LHD loader, to the mine power system. It is built to be dragged, reeled and flexed, and usually carries grounding plus ground-check or pilot conductors so that the earth circuit can be monitored.

02Should I choose an ICEA or a VDE mining cable?

Choose the family your machine and site electrical rules were designed around; voltage alone does not make the two interchangeable. ICEA types use type letters such as W, G-GC and SHD-GC, one voltage figure such as 2000 V and AWG/kcmil sizes. VDE types use codes such as NSSHCGEÖU or (N)TSCGEWÖU, U0/U ratings from 0.6/1 kV to 20/35 kV, mm² sections and Class 5 conductors.

03What is the difference between Type G-GC, Type W and Type SHD-GC?

Type G-GC is a 2000 V round cable with three power cores, two grounding conductors and one ground-check conductor for continuous miners, shuttle cars and drills. Type W is rated 600/2000 V with 2 to 5 cores in flat or round form and no bare grounds. Type SHD-GC adds a copper braid over each power core and covers 2 kV to 25 kV for shovels, drills and mine feeders.

04Which cables carry ground-check or pilot conductors?

ICEA Type G-GC and SHD-GC have two grounding conductors and one yellow-insulated ground-check conductor, and Type MP-GC feeders have two bare grounds and one 8-gauge insulated ground check. Type W is used where bare grounding conductors are not required. On the VDE side, NSSHCGEÖU(V) carries control cores with concentric monitoring conductors, and (N)TMCGETMPU has a dedicated ground-check conductor.

05Are all cables in this category trailing cables?

No. Feeder, hoist, locomotive-wire and signal cables are listed here but are not trailing types. Type MP-GC and the (N)3GHSSYCY and (N)3GHSSHCH tunnel cables feed distribution equipment, NTMTWOEU hangs in hoist shafts, the DLO cables serve as motor, battery and locomotive leads, and P1209 and LiYCY carry monitoring or signal circuits. Choose a trailing or reeling type for machines that drag or reel their cable.

06What should I send with a mining trailing cable RFQ?

The type designation or existing cable marking (ICEA or VDE); rated voltage, number of cores and conductor size in AWG/kcmil or mm²; grounding, ground-check, pilot, control or fibre-optic cores; the machine and its movement, whether trailing, reeling (drum type and speed), festoon, suspended or fixed; water, oil, temperature, flame or LSZH requirements; and length per drum and total length.

Why Choose Us

A special-cable manufacturer in Taicang, Suzhou, making heavy-duty and special cables since 2014.

Certified Quality

UL and cUL, VDE, Korea KC, China MA and US MSHA approvals for the certified types, CE verification of conformity, and ISO 9001 quality management.

200+ Sets of Equipment

More than 200 sets of advanced production and test equipment at home and abroad, from compounding to final electrical testing.

15 Senior Cable Engineers

Constructions engineered to VDE, ICEA, IEC and NEK 606 standards and checked against the real duty cycle of your equipment.

1,500+ Cable Types

0.6/1 kV to 35 kV heavy-duty rubber cables, reeling and festoon crane cables, submersible, marine, ROV and high-temperature cables.

Custom Cable Design

Special constructions, fibre-optic elements, colours, printing and lengths built to the specification of your project.

Worldwide Project Supply

Cables working in tunnel engineering, marine and offshore equipment, mining, petrochemical, steel and urban construction projects around the world.

Can’t Find What You Need?

Send us the equipment, voltage, cores and operating conditions and our engineers will propose a cable construction and quotation.