EV Charging SWA Cable with CAT5e Data, 3-Core 4mm² or 6mm², 600-1000V

EV charging SWA cable combining a three-core 4mm² or 6mm² power cable with four-pair CAT5e data in a double-sheathed, steel wire armoured construction, rated 600-1000V with a 4kV test voltage for charge-point installations.

  • Voltage rating600-1000V
  • Test voltage4kV
  • Power cores3 × 4 mm² or 3 × 6 mm²
  • Data element4-pair CAT5e
  • ArmourSteel wire armour (SWA)
  • Overall diameter17.6 mm / 19.5 mm
  • Temperature range-30°C to +80°C
  • Min. bending radius10 × overall diameter
Category:
Product overview

This cable combines a three-core power cable and a four-pair CAT5e data cable in one double-sheathed, steel wire armoured construction for electric vehicle charge points. The power cores are Class 5 flexible stranded copper with XLPE insulation in 4 mm² or 6 mm², and the data element is a CAT5e cable with Class 1 solid copper conductors and PVC insulation.

One cable carries the charger supply and the communication link from the building to the charge point, so an installer lays a single armoured run instead of a power cable plus a separate data cable. The armour gives mechanical protection on external routes, and the cable is rated 600-1000V with a 4kV test voltage.

Browse the EV charging cable category for related cables.

Application & Features

Home, workplace and small commercial charge points usually take a single-phase supply and need a data connection for network access, back-office communication or load management. A combined cable lets the power and CAT5e data follow the same route from the distribution board or network cabinet to the charger. The 4 mm² version suits shorter or lower-current runs; the 6 mm² version is chosen when the charger current, route length or voltage drop call for the larger conductor.

The steel wire armour and outer PVC sheath protect the cable on routes clipped to walls and masonry or run along structures outdoors, where an unarmoured cable would need additional containment. The route design must accept the 10 × overall diameter bend radius, and the armour must be terminated in suitable glands and bonded as the installation design requires. The CAT5e pairs are terminated separately at the charger's data interface.

  • EV charge pointsCombined power and CAT5e data for installations that need both at the charger.
  • Power and monitoringMonitoring or communication data follows the power route in the same cable.
  • External protected routesSWA mechanical protection and PVC sheathing for exposed runs.
  • Masonry or structure routesClipped runs on masonry and structures that accept the 10 × overall diameter bend radius.
EV charge point being installed in a visitor car park behind safety barriers, where an armoured power and CAT5e data cable is laid to each post
Charge points being installed in a visitor car park. Each post needs a supply and a data link, which a combined armoured power-and-CAT5e cable delivers in one run. Photo: John Lucas, CC BY-SA 2.0, via Wikimedia Commons.

Specifications

Values from the current TEBAOFLEX EV SWA + CAT5e datasheet. The final construction is confirmed on the approved datasheet for your order.

Electrical and construction data

Parameter Value
Voltage rating 600-1000V
Test voltage 4kV
Minimum bend radius 10 × overall diameter
Temperature range -30°C to +80°C
Power conductor Class 5 flexible stranded copper
Data conductor Class 1 solid copper, four-pair CAT5e data
Power insulation XLPE
Data insulation PVC
Bedding Extruded PVC compound
Armour Steel wire armour (SWA)
Sheath PVC power and CAT5 data sheaths

Cable dimensions

Reference construction Power size Cores and data Overall diameter Weight
3×4mm² + CAT5e 4mm² 3 core and CAT5e 17.6mm 455kg/km
3×6mm² + CAT5e 6mm² 3 core and CAT5e 19.5mm 740kg/km

Core and pair identification

Element Identification
Power cores Brown, blue, green/yellow
Data pairs Blue, orange, green and brown pairs with white identification

Selection note: ask our engineers to confirm the current ratings and data performance figures. Check current, voltage drop, data termination, armour bonding, bend radius and route temperature for your installation, and ask our engineers to confirm the size before ordering.

Standards & References

  • Cable referencesManufactured to IEC 60228 (conductors), IEC 60502-1 (power cable construction) and IEC 60332-1-2 (flame propagation, single cable).
  • Power and data scopeCombined three-core power and four-pair CAT5e data cable in a double-sheathed SWA design, rated 600-1000V with a 4kV test voltage.
  • Installation documentationConfirm the charge-point design, data interface, armour bonding, cable entry and any CPR or inspection documentation required by the project.
  • ApprovalsThird-party certificates, CPR declarations and marking requirements are confirmed and quoted per order.

Construction

The cable groups a power circuit and a data circuit under one armour. The three insulated power cores and the CAT5e data cable are laid up, bedded in extruded PVC, armoured with steel wire and covered by the outer PVC sheath.

  • Power conductors: Class 5 flexible stranded copper, 4 mm² or 6 mm², three cores (brown, blue, green/yellow).
  • Power insulation: XLPE on each power core.
  • Data cable: Four-pair CAT5e with Class 1 solid copper conductors and PVC insulation, in its own PVC sheath.
  • Bedding: Extruded PVC compound around the power cable construction.
  • Armour: Steel wire armour (SWA) for mechanical protection.
  • Outer sheath: PVC outer sheath, completing the double-sheathed construction.

FAQ

Why combine power and CAT5e data in one cable?

Networked charge points need a supply and a data link. Combining them in one armoured cable means one trench or wall run, one set of fixings and fewer glands, and the data link cannot be forgotten or routed separately by mistake.

Should I choose 4mm² or 6mm²?

Both versions share the same construction. The choice depends on the charger current, the route length (voltage drop) and the installation method. Send the charger rating and route length and our engineers will confirm the size.

Is there an unarmoured or LSZH version?

Yes. The unarmoured power and CAT5e data cable suits protected indoor routes. Where LSZH sheaths and a screened Cat6A data element are specified, see the armoured Cat6A LSZH cable.

What should I send for a quotation?

Send the power size (4 mm² or 6 mm²), quantity and cut lengths, the installation route, the charger type and any CPR class, marking or inspection documents your project requires.

Request a quote

Request this cable.

Send the power size, length, installation route, charger type and any CPR or documentation requirement.

Request a quotation

Contact directly

Talk to our cable team.


Quality Assurance

Testing at every stage in our own workshop and laboratory, from incoming copper to the packed drum.

Bare copper wire bobbins inspected before stranding at the TEBAOFLEX factory

Raw Material Inspection

Every batch of copper rod, rubber compound and reinforcing material is checked before it reaches the line.

  • Copper: conductor resistance, elongation and surface condition on incoming rod and drawn wire
  • EPR, CPE, PUR and silicone compounds: hardness, tensile strength, elongation and ageing samples from each mix
  • Suppliers and batch numbers are recorded so every drum can be traced back to its materials
Operator monitoring an extrusion line control panel in the TEBAOFLEX workshop

Manufacturing Process Control

Stranding, insulation extrusion, core assembly and sheathing run under recorded process parameters.

  • Class 5/6 stranding with lay length and tension monitored for trailing and reeling flexibility
  • Continuous-vulcanisation extrusion with wall thickness and spark tests logged on every length
  • Operators sign off each stage before the cable moves to the next machine
3.5 kV voltage withstand test station in the TEBAOFLEX laboratory

Electrical Testing

Finished lengths go through the routine tests required by the referenced VDE, ICEA, IEC or NEK standard.

  • Conductor resistance and insulation resistance on every length
  • Voltage withstand (3.5 kV and higher) and partial-discharge measurement in the shielded HV laboratory
  • Screen and pilot-core continuity checks for mining and reeling constructions
Tensile testing machine for conductor and sheath samples

Mechanical and Ageing Tests

Samples from production are tested for the duty a mining, crane or submersible cable will actually see.

  • Tensile strength and elongation of insulation and sheath before and after ageing
  • Hot-set, ozone, oil-immersion and low-temperature bending tests
  • Constant-temperature water bath for insulation resistance of submersible constructions
Single-cable vertical flame test chamber

Flame Test and Final Inspection

Before packing, the cable is checked against the order and the flame-performance requirement of its standard.

  • Single-cable vertical flame test to IEC 60332-1-2 where specified
  • Metre marking, printing, drum length and appearance inspection
  • Test report and packing list issued with every shipment