YnOGYekm 0.6/1 kV Braid-Screened Mining Cable

YnOGYekm mining cable combines flexible Class 5 copper with individual copper-wire braid screens for 0.6/1 kV equipment supply.

  • PVC insulation, inner sheath and flame-retardant outer sheath.
  • Five- and seven-conductor layouts with one or three control cores.
  • Power sections: 2.5–120 mm² across the listed configurations.
  • Temperature range: -30 to +70 °C.
  • Minimum bend radius: 6 × OD fixed; 10 × OD movable.

Specify the complete core schedule, installation duty and mine classification for quotation.

YnOGYekm Screened Cable for Mining Equipment

YnOGYekm mining cable is a 0.6/1 kV flexible PVC cable with individual copper-wire-and-plastic-thread screens on the power cores. It supplies stationary and portable mining equipment through three power conductors, an uninsulated protective conductor and either one or three control cores. PVC insulation, an inner sheath and a flame-retardant outer sheath complete the construction.

Start a replacement inquiry with the full conductor schedule. The five-core range contains six configurations with power sections from 2.5 to 25 mm². The seven-core range contains seven configurations from 16 to 120 mm². These are different control arrangements; a larger power conductor does not automatically provide the same protective or control-core sizes.

  • Identify the screen: specify the individual braid construction and the equipment’s termination requirements.
  • Count control circuits: select one or three control cores before comparing cable diameter.
  • Check the route: fixed and movable installations use different minimum bend radii.
  • Confirm the mine classification: provide the methane and coal-dust classification and the required acceptance documents.

The technical sections separate construction details, installation decisions and complete dimensional and electrical tables. Compare the core schedule, maximum diameter and weight together when selecting a replacement. Browse the mining cable range for other constructions, or download the YnOGYekm datasheet.

Construction

YnOGYekm uses a separate braid of copper wires and plastic thread around each power core. Three screened power cores, an uninsulated copper protective conductor and the selected control-core arrangement form the cable assembly.

YnOGYekm five-conductor cross-section with individual braid screens, protective conductor and brown control core
YnOGYekm construction with individual copper-wire and plastic-thread braid screens. Match the complete power, protective and control-core arrangement.
YnOGYekm core identification and material layers
ComponentYnOGYekm construction
ConductorsCopper, Class 5 to PN-EN 60228
Power-core insulation and colorsPVC; natural, red and blue
Individual power-core screenCopper wire braid with plastic thread on each power core
Protective conductorUninsulated copper
Control identificationBrown for one control core; natural, red and blue for three control cores
AssemblyPower and control cores assembled around the protective conductor
Inner sheathPVC
Outer sheathSpecial flame-retardant PVC; confirm color and marking with the order

Specify the braid and its termination

Screen construction is part of the model selection. Give the termination supplier the individual-braid arrangement and the equipment connection drawing; do not substitute a compound screen merely because the voltage and conductor sizes match.

Identify the complete core schedule

The illustrated five-core section contains three power cores, one protective conductor and one control core. Seven-core orders add three control cores instead. Confirm the control count, each control-core area and protective-conductor area separately.

Confirm sheath color with the order

The product view and cross-section show a black outer sheath. Confirm the required color, including any yellow-sheath requirement, and the cable marking when placing the order.

Applications

YnOGYekm supplies stationary and portable electrical equipment in open-pit, strip and underground mines. The application range includes methane hazard classes a, b and c and coal-dust hazard classes A and B. Match the mine classification and required acceptance documentation to the installation before ordering.

Stationary hydraulic power pack in a mine maintenance bay with a supported black electrical supply cable
A stationary hydraulic power pack in a mine maintenance bay. The supply cable follows a protected route clear of the access aisle.

One control circuit or three

Use the equipment wiring diagram to choose the five- or seven-core layout. A seven-core cable provides three control conductors, but their individual cross-sections vary with the selected configuration; spare core count alone is not enough to choose a replacement.

Plan bends and cable handling together

Allow at least 6 × outside diameter for fixed bends and 10 × outside diameter for movable bends. Check clearances at cable glands and changes in direction using the selected configuration's maximum diameter. Include cable length and weight when reviewing support and handling arrangements.

Describe the movement and environment

For repeated travel, drum service or torsion, send the movement pattern and handling arrangement for engineering review. Include exposure to water, chemicals, oil or mechanical impact so cable protection and suitability can be confirmed for the route.

Specifications

Select YnOGYekm by its full power, protective and control-conductor configuration. D in the bend requirements means the finished cable outside diameter; the dimensional tables give maximum OD.

YnOGYekm voltage, temperature and bending requirements
ParameterValue
Rated voltage U₀/U0.6/1 kV
Operating temperature range-30 to +70 °C
Maximum short-circuit temperature160 °C
Minimum bend radius, fixed6 × D
Minimum bend radius, movable10 × D
Power-conductor range2.5–120 mm² across listed configurations
Total conductors5 or 7

Compare the complete configuration

YnOGYekm 3x25+16+3x2.5 identifies three 25 mm² power cores, one 16 mm² protective conductor and three 2.5 mm² control cores. A 3x25+16+16 configuration has one 16 mm² control core instead. Keep that distinction in the purchase description and termination schedule.

YnOGYekm five-conductor configurations: 3 power + 1 protective + 1 control
Model + configurationTotal conductorsPower (mm²)Protective (mm²)Each control (mm²)Max. OD (mm)Weight (kg/km)
YnOGYekm 3x2.5+2.5+2.552.52.52.518.6505
YnOGYekm 3x4+4+4544420.0619
YnOGYekm 3x6+6+4566423.6810
YnOGYekm 3x10+10+651010625.81110
YnOGYekm 3x16+16+10516161029.81560
YnOGYekm 3x25+16+16525161635.62340
YnOGYekm seven-conductor configurations: 3 power + 1 protective + 3 controls
Model + configurationTotal conductorsPower (mm²)Protective (mm²)Each control (mm²)Max. OD (mm)Weight (kg/km)
YnOGYekm 3x16+16+3x1.5716161.530.31600
YnOGYekm 3x25+16+3x2.5725162.538.12175
YnOGYekm 3x35+16+3x2.5735162.541.12770
YnOGYekm 3x50+25+3x475025447.53760
YnOGYekm 3x70+35+3x477035454.15010
YnOGYekm 3x95+35+3x479535463.06410
YnOGYekm 3x120+50+3x4712050467.58130

Reference electrical data

Use the power-conductor section to find the corresponding values. Confirm installation method, ambient temperature, grouping and load profile before selecting a current rating for the actual cable route.

YnOGYekm power-conductor electrical data
Power section (mm²)Reactance (Ω/km)Inductance (mH/km)Capacitance (µF/km)Reference current capacity (A)
2.50.1260.400.4227
40.1130.360.5537
60.1100.350.5747
100.1040.330.6266
160.0960.280.6690
250.0940.280.67115
350.0900.270.76144
500.0880.260.81176
700.0840.250.92213
950.0830.250.96250
1200.0800.241.08290

Standards

Use the following conductor, flame-performance and electrical-test references when specifying YnOGYekm. Keep the power-core and control-core voltage tests separate in the inspection requirements.

YnOGYekm conductor, flame and voltage-test references
Reference or testRequirement / role
PN-EN 60228Class 5 copper conductor reference
PN-EN 60332-1Single-cable flame-performance reference
PN-EN 60332-3-24 / IEC 60332-3Bunched-cable flame-performance references
Oxygen indexGreater than 29
Power-conductor test voltage3.2 kV
Control-conductor test voltage2 kV

Send the required cable marking, test reports and mine acceptance documentation with the inquiry. Open the YnOGYekm technical datasheet (PDF) for the full specification tables.

Request Quote

Send the YnOGYekm configuration, required voltage, length and quantity, installation duty, equipment connection details and sheath color. Include the protective-core, screen or armor requirements that apply to the selected construction, together with inspection requirements.

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    You can also use our technical contact form.

    Quality Assurance

    Testing at every stage in our own workshop and laboratory, from incoming copper to the packed drum.

    Bare copper wire bobbins inspected before stranding at the TEBAOFLEX factory

    Raw Material Inspection

    Every batch of copper rod, rubber compound and reinforcing material is checked before it reaches the line.

    • Copper: conductor resistance, elongation and surface condition on incoming rod and drawn wire
    • EPR, CPE, PUR and silicone compounds: hardness, tensile strength, elongation and ageing samples from each mix
    • Suppliers and batch numbers are recorded so every drum can be traced back to its materials
    Operator monitoring an extrusion line control panel in the TEBAOFLEX workshop

    Manufacturing Process Control

    Stranding, insulation extrusion, core assembly and sheathing run under recorded process parameters.

    • Class 5/6 stranding with lay length and tension monitored for trailing and reeling flexibility
    • Continuous-vulcanisation extrusion with wall thickness and spark tests logged on every length
    • Operators sign off each stage before the cable moves to the next machine
    3.5 kV voltage withstand test station in the TEBAOFLEX laboratory

    Electrical Testing

    Finished lengths go through the routine tests required by the referenced VDE, ICEA, IEC or NEK standard.

    • Conductor resistance and insulation resistance on every length
    • Voltage withstand (3.5 kV and higher) and partial-discharge measurement in the shielded HV laboratory
    • Screen and pilot-core continuity checks for mining and reeling constructions
    Tensile testing machine for conductor and sheath samples

    Mechanical and Ageing Tests

    Samples from production are tested for the duty a mining, crane or submersible cable will actually see.

    • Tensile strength and elongation of insulation and sheath before and after ageing
    • Hot-set, ozone, oil-immersion and low-temperature bending tests
    • Constant-temperature water bath for insulation resistance of submersible constructions
    Single-cable vertical flame test chamber

    Flame Test and Final Inspection

    Before packing, the cable is checked against the order and the flame-performance requirement of its standard.

    • Single-cable vertical flame test to IEC 60332-1-2 where specified
    • Metre marking, printing, drum length and appearance inspection
    • Test report and packing list issued with every shipment