Open-Cast Mining NTSCGEWOEU W 3E Cable in Water & Trailing

MV NTSCGEWOEU W /3E with shield cable is suitable to work in sewage,salt and brackish water, max. depth 300 meters.
MV NTSCGEWOEU W /3E withou shield layer cable is suitable to work in sewage, salt and brackish water
MV NTSCGEWOEU Trailing Cable for large material handling machines, e.g. excavators in open-cast mines subject to extremely high mechanical stresses in which abrasion and chaffing stresses are to be expected in trailing operation.

MV NTSCGEWOEU W /3E  Cable Construction

NTSCGEWOEU-W 3+3

Voltage: 1.8/3kV, 3.6/6kV, 6/10kV, 8.7/15kV
Conductors:
Flexible stranded tinned copper conductor, class 5 according to DIN VDE 0295.
Inner Conductor Layer: Semiconductive layer.
Insulation: Rubber type 3GI3, EPR compound with improved electrical and mechanical characteristics (DIN VDE 0207, Part 20)
Outer Conductor Layer: Semiconductive layer.
Earth Conductor: Split into three in the outer interstices or Individual concentric distributed over core insulating coverings (coding /3E) or incorporated as a fourth core.
Core colours: natural colouring with black semiconductive rubber with printed white digits 1-3
Wrapping: semiconductive, reinforced, swellable, binding and separating tape waterproof
Inner Sheath: EPR Rubber compound type GM1b with characteristics of waterproof and prevention of formation of water bubbles.
Outer Sheath: Waterproof rubber type 5GM3 (acc. to DIN VDE 0207, Part 21), color: red
Application: These cables are designed for operation in water for connection to dredgers, floating docks, pumps, etc., in applications where high mechanical stresses are to be expected, also suitable for use in sewage, salt water and brackish water at water depths of up to 500 m.

NTSCGEWOEU W 3E Cable Operating temperature:

Fixed systems: -40°C to 90°C
Flexible operation: -25°C to 80°C
Maximum permissible water temperature: 40°C
Maximum permissible operating
temperature of the conductor: 90°C
Maximum conductors operating
temperature in short-circuit: 250°C
Tensile load: 15N/mm²
Torsional stresses: +/- 100°/m
Min. bending radius: according to DIN VDE 0298, Part 3
Operating voltage:
U0 /U= 3,6/6kV to 18/30kV
Test voltage: 11kV to 43kV
Standard: according to DIN VDE 0250, p.813

MV NTSCGEWOEU W  Cable With Shield Construction

NTSCGEWOEU-W

Voltage: 1.8/3kV, 3.6/6kV, 6/10kV, 8.7/15kV
Conductor: Electrolytic copper, tinned, finely stranded (class 5)
Insulation: Basic material EPR, Compound type: 3GI3
Electrical field control:  Inner and outer layer of semi conductive rubber compound and metallic concentric screen on each core
Core identification:  Natural coloring with black semi conductive rubber
Core arrangement:  Three main conductor laid-up with individual concentric protective-earth conductors distributed over the insulation of the three main cores
Inner sheath:  EPR inner sheath with special water-proof characteristics for prevention of formation of water bubbles, Compound type: GM1B
Outer sheath: Basic material: synthetic elastomer compound e.g. CM (particularly water-proof), Compound type: 5GM3, Color: Red
Application:  NTSCGEWOEU W Power supply cable for use in open-pit mining facilities designed for operation in water and exposed to high mechanical stresses, e.g.for connection to dredgers,floating docks, submersible pumps,etc.Cables are suitable to work in sewage,salt and brackish water.

Ambient temperature:
fixed installation: -40 °C to 80 °C
flexible operation: -25 °C to 80 °C

Max. permissible conductor temp.: 90 °C
Max. short-circuit temp. at conductor: 250 °C
De-rating factors: acc. to DIN VDE 0298-4

Mechanical parameters:
Max. tensile load per conductor: 15 N/mm²
Torsional stresses: +/-25 °/m
Bending radius: acc. to DIN VDE 0298-3

NTSCGEWOEU -50 °C Open-cast Mining Trailing Cable

NTSCGEWOEU open-carst cable

Conductors: Flexible stranded tinned copper conductor, class 5 according to DIN VDE 0295.
Inner Conductor Layer: Semiconductive layer.
Insulation: Rubber type 3GI3 .
Outer Conductor Layer: Semiconductive layer.
Earth Conductor: Split into three in the outer interstices or Individual concentric distributed over core insulating coverings (coding /3E).
Reinforcing Tape: Extremely tear-resistant reinforcing tape.
Inner Sheath: Rubber type 5GM5, abrasion and tear resistant, oil and ozone resistant.
Outer Sheath: Rubber type 5GM5, abrasion and tear resistant, oil and ozone resistant, inseparably bonded with inner sheath.
Application: These cables are used as power supply or connection cables for large material handling machines, e.g. excavators in open-cast mines subject to extremely high mechanical stresses. Particularly suitable for applications in which abrasion and chaffing stresses are to be expected in trailing operation.

Characteristics

•resistant to: oil, ozone, solvents, petrol, acids, chemicals, greases
•abrasion-resistant
•Excellent tear, impact and abrasion resistant
•Flame retardant
•UV, sunlight, ozone and oil resistant
•Embossing marking for easy identication

Tests

•Flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332- 1-2 / IEC 60332-1-2
•Oil-resistant acc. to DIN VDE 0473-811-404 / DIN EN 60811-404/ IEC 60811-40

Standads:

Construction: DIN VDE 0250-813
General Requirements: DIN VDE 0250-1
Guide Use: DIN VDE 0298-3
Electrical Tests: DIN VDE 0472-501, 503, 508
Non-Electrical Tests: DIN VDE 0472-401. 402,602,303, 615
Under Fire Condition Tests: DIN VDE 0472-803, 804
Water resistance: EN 50525-2-21 (HD 22.16)
Weather resistance: Unrestricted use outdoors and indoors, resistant to ozone, UV and moisture

NTSCGEWOEU W/3E Cable for in waterNTSCGEWOEU -50°C Trailing Cable
Number of cores x Conductor diameter Outer
diameter
Outer
diameter
Weight
(approx.)
Permissible tensile force Con-
ductor resis- tance at 20°C max.
Nominal
operating capacitance
Induc-
tance nom.
Short
Circuit Current (conductor)
cross section max.mm min.mm max.mm  kg/km max.N Ω/km µF/km mH/ km kA
NTSCGEWOEU W 3.6/6 kV
NTSCGEWOEU W 3E 3×25+3×25/3 6.4 36.1 39.1 2370 1125 0.795 0.33 0.33 3.58
NTSCGEWOEU W 3E 3×35+3×25/3 7.6 37.8 40.8 2600 1575 0.565 0.38 0.31 5.01
NTSCGEWOEU W 3E 3×50+3×25/3 9 42.1 45.1 3320 2250 0.393 0.43 0.3 7.15
NTSCGEWOEU W 3E 3×70+3×35/3 10.9 47.4 50.4 4350 3150 0.277 0.5 0.28 10.01
NTSCGEWOEU W 3E 3×95+3×50/3 12.6 53.2 57.2 5850 4275 0.21 0.52 0.27 13.59
NTSCGEWOEU W 3E 3×120+3×70/3 14.1 56.4 60.4 6700 5400 0.164 0.56 0.27 17.16
NTSCGEWOEU W 3E 3×150+3×70/3 16 60.4 64.4 8060 6750 0.132 0.63 0.26 21.45
NTSCGEWOEU W 3E 3×185+3×95/3 17.8 66.9 70.9 9450 8325 0.108 0.69 0.25 26.46
NTSCGEWOEU W 3E 3×240+3×120/3 20.4 72.4 76.4 11000 10800 0.0817 0.77 0.25 34.32
NTSCGEWOEU W 6/10 kV
3×25+3×25/3 6.4 41.7 44.7 2910 1125 0.795 0.24 0.36 3.58
3×35+3×25/3 7.6 44.3 47.3 3380 1575 0.565 0.27 0.34 5.01
3×50+3×25/3 9 48.9 52.9 4310 2250 0.393 0.3 0.32 7.15
3×70+3×35/3 10.9 53.8 57.8 5380 3150 0.277 0.34 0.31 10.01
3×95+3×50/3 12.6 57.4 61.4 6420 4275 0.21 0.38 0.29 13.59
3×120+3×70/3 14.1 60.6 64.6 7270 5400 0.164 0.42 0.29 17.16
3×150+3×70/3 16 66.4 70.4 9000 6750 0.132 0.46 0.28 21.45
3×185+3×95/3 17.8 71.1 75.1 10100 8325 0.108 0.5 0.27 26.46
3×240+3×120/3 20.4 77.9 82.9 12000 10800 0.0817 0.56 0.26 34.32
NTSCGEWOEU W 8.7/15  kV
3×25+3×25/3 6.4 46.4 49.4 3440 1125 0.795 0.2 0.39 3.58
3×35+3×25/3 7.6 48.4 52.4 3730 1575 0.565 0.22 0.37 5.01
3×50+3×25/3 9 53.3 57.3 4880 2250 0.393 0.24 0.35 7.15
3×70+3×35/3 10.9 57.3 61.3 5780 3150 0.277 0.28 0.33 10.01
3×95+3×50/3 12.6 63.9 67.9 7100 4275 0.21 0.31 0.31 13.59
3×120+3×70/3 14.1 67.1 71.1 8250 5400 0.164 0.33 0.3 17.16
3×150+3×70/3 16 72 76 9450 6750 0.132 0.37 0.29 21.45
3×185+3×95/3 17.8 76.6 80.6 11690 8325 0.108 0.4 0.28 26.46
3×240+3×120/3 20.4 82.6 87.6 12700 10800 0.0817 0.44 0.27 34.32
Number of cores x cross section Conduc- tor
diameter max.
Outer
diameter min.
Outer
diameter max.
Weight
(approx.)
Permis- sible
tensile force
Con-
ductor resis- tance
at 20°C max.
Nominal
operating
capacitance
Induc-
tance
nom.
Current
carrying
capacity (1)
Short
Circuit Current
(conduc- tor
mm mm mm kg/km N Ω/km µF/km mH/ km A kA
NTSCGEWOEU 3.6/6 kV
NTSCGEWOEU 3×16+2×10+10 5 41 45 2270 1200 1.24 0.2 0.39 99 2.29
NTSCGEWOEU 3×16+2×16+16 5 40.5 44.5 2469 1200 1.24 0.2 0.39 99 2.29
NTSCGEWOEU 3×25+2×16+16 6.2 43.5 47.5 2790 1875 0.795 0.23 0.36 131 3.58
NTSCGEWOEU 3×35+2×16+16 7.5 46.5 50 3280 2625 0.565 0.26 0.34 162 5.01
NTSCGEWOEU 3×50+2×16+16 9 49.5 54 3900 3750 0.393 0.29 0.32 202 7.15
NTSCGEWOEU 3×70+2×25+16 10.6 55 59.5 5020 5250 0.277 0.34 0.3 250 10.01
NTSCGEWOEU 3×95+2×25+16 12.6 58.5 63 5860 7125 0.21 0.37 0.29 301 13.59
NTSCGEWOEU 3×120+2×35+16 14.8 65.5 70 7410 9000 0.164 0.41 0.28 352 17.16
NTSCGEWOEU 3×150+2×35+16 16 69.8 73.4 8456 11250 0.132 0.44 0.27 404 21.45
NTSCGEWOEU 3×185+2×50+16 17.7 72.7 77.2 9955 13875 0.108 0.48 0.27 461 26.46
NTSCGEWOEU 3×240+2×70+16 20.3 80.1 84.6 12618 18000 0.0817 0.54 0.26 540 34.32
NTSCGEWOEU 3×300+2×95+16 31.3 84 89 15075 22500 0.0654 0.78 0.24 620 42.9
NTSCGEWOEU 6/10 kV
3×16+2×16+16 5 42.5 46.5 2613 1200 1.24 0.19 0.4 99 2.29
3×25+2×16+16 6.2 46.1 49.6 3041 1875 0.795 0.21 0.37 131 3.58
3×35+2×16+16 7.5 52.5 56.5 3470 2625 0.565 0.24 0.35 162 5.01
3×50+2×16+16 9 52 56.5 4080 3750 0.393 0.27 0.33 202 7.15
3×70+2×25+16 10.6 57 61.5 5240 5250 0.277 0.31 0.31 250 10.01
3×95+2×25+16 12.6 61.6 66.1 6503 7125 0.21 0.34 0.3 301 13.59
3×120+2×35+16 14.8 64.2 68.7 7630 9000 0.164 0.38 0.29 352 17.16
3×150+2×35+16 16 70.6 75.1 8694 11250 0.132 0.41 0.28 404 21.45
3×185+2×50+16 17.7 74.4 78.9 10467 13875 0.108 0.44 0.27 461 26.46
3×240+2×70+16 20.3 81.8 86.3 12895 18000 0.0817 0.49 0.26 540 34.32
3×300+2×95+16 31.3 87.5 92.5 15693 22500 0.0654 0.71 0.24 620 42.9
NTSCGEWOEU 8.7/15 kV
3×16+2×16+16 5 47 51 3041 1200 1.24 0.16 0.43 105 2.29
3×25+2×16+16 6.2 52 56 3677 1875 0.795 0.18 0.4 139 3.58
3×35+2×16+16 7.5 55.4 59.9 4138 2625 0.565 0.2 0.37 172 5.01
3×50+2×16+16 9 57.5 61.5 4813 3750 0.393 0.22 0.35 215 7.15
3×70+2×25+16 10.6 64 68 6159 5250 0.277 0.26 0.33 265 10.01
3×95+2×25+16 12.6 68.2 72.7 7123 7125 0.21 0.28 0.32 319 13.59
3×120+2×35+16 14.8 72.9 77.4 8322 9000 0.164 0.31 0.31 371 17.16
3×150+2×35+16 16 75.4 79.9 9645 11250 0.132 0.33 0.3 428 21.45
3×185+2×50+16 17.7 80.9 85.4 11208 13875 0.108 0.36 0.29 488 26.46
3×240+2×70+16 20.3 86.5 91 13991 18000 0.0817 0.4 0.28 574 34.32
3×300+2×95+16 31.3 92 97 16533 22500 0.0654 0.57 0.25 660 42.9

Advantage of Tebaoflex NTSCGEWOEU Cable

Tebaoflex Cable Group specializes in customizing premium NTSCGEWOEU rubber cables that fully comply with top global industrial manufacturing standards, tailored for heavy machinery, mobile engineering equipment, outdoor fixed laying and frequent dynamic moving industrial scenarios.
✔ Industrial-Grade Reinforced Durability – Built with braided reinforcing layer and thickened heavy rubber sheath, resisting heavy mechanical extrusion, sharp friction, tensile damage and industrial slag erosion, perfectly fit mining equipment, port cranes, construction machinery and workshop mobile power systems.
✔ Full International Safety Certified – Strictly compliant with IEC, VDE and EU unified industrial cable norms, passed full electrical safety, flame retardant and environmental protection tests, zero leakage risk, safe for industrial power transmission and signal synchronous operation.
✔ All mining cable products support factory direct supply, third-party inspection and OEM bulk order service for global industrial clients.