0.6/1kV NSSHCGEÖU(V) Mining Cable 3×70, 3×95, 3×120, 3×150
- NSSHCGEÖU(V) is a heavy-duty flexible mining cable complying with DIN VDE 0250 Part 812, rated at 0.6/1kV. It is specially designed for coal cutters, featuring EPR insulation, chloroprene outer sheath, integrated pilot cores and concentric earthing armour.
- It adapts to harsh working conditions with frequent trailing, reeling, bending, tension and impact loads.
- Suitable for wet, oily, dusty and hazardous mining areas, and allows temporary service in shallow water.
0.6/1kV NSSHCGEÖU(V) Mining Cable Construction

- Conductor: flexible tinned copper conductor Cl. 5, acc to IEC 60228, DIN VDE 0295
- Insulation: rubber EPR type 3GI3
- Outer semi-conductive layer: semi-conducting rubber compound
- Monitoring conductor: tinned copper wires laying concentric around each control cores
- Monitor semi-conductive layer: semi-conducting rubber compound
- Inner sheath: rubber EPR type GM1b
- Earth conductor: copper/steel wires laying concentric between inner and outer sheath
- Outer sheath: yellow (similar to RAL 1021), rubber PCP type 5GM5
NSSHCGEÖU(V) Cable Feature
- Ozone and moisture resistance
- very good for monitoring the cables with
- appropriate monitoring equipement
- outdoor/indoor use
- coal-mining use
- used in cable chains
NSSHCGEÖU(V) Technical Details
| Temperature range: | |
| Fixed installation: | – 40°C + 80°C |
| Flexible installation: | – 25°C + 80°C |
| Temperature on conductor: | |
| In service: | + 90°C |
| In short circuit: | + 200°C |
| Nominal voltage: | Uo/U 0.6/1 kV |
| Test voltage: | 3000 V |
| Operating voltage: | A.C. Uo/U = 0.7/1.2 kV max. D.C. Uo/U = 0.9/1.8 kV max. |
| Tensile strength static: | 15 N/mm2 (please check min. bending radius applications) |
| Fire resistance: | DIN VDE 0482, EN/IEC 60332-1-2 |
| Oil resistance: | DIN VDE 0473, part 811-2-1, par. 10, EN 60811-2-1, IEC EN 60811-1-2 |
Main Applications
This cable is used for power supply and signal control of heavy mobile mining machinery including coal cutters, roadheaders and LHD loaders in coal mines and metal mines.
It adapts to harsh working conditions with frequent trailing, reeling, bending, tension and impact loads. Suitable for wet, oily, dusty and hazardous mining areas, and allows temporary service in shallow water.
Key Technical Parameters
- Rated voltage: 0.6/1kV
- Operating temperature range: -25°C ~ +90°C
- Minimum bending radius: 10 times of cable outer diameter
- Executive standard: DIN VDE 0250 Part 812
Ordering Information of NSSHCGEÖU(V)
| Size | No. of cores x cross section |
Outer- Ø | Copper weight | Cable weight approx. | Tensile strength |
| AWG(no.*) | n x mm2 | ca. mm ± 10% | kg/km | kg/km | N |
| 4 | 3×25/16KON+3x(1.5ST KÖN/1.5 UL KON) | 38 | – | 2850 | 1125 |
| 2 | 3×35/16KON+3x(1.5ST KÖN/1.5 UL KON) | 43 | – | 3070 | 1575 |
| 1 | 3×50/35KON+3x(1.5ST KÖN/1.5 UL KON) | 46 | – | 4010 | 2250 |
| 2/0 | 3×70/35KON+3x(1.5ST KÖN/1.5 UL KON) | 53 | – | 4970 | 3150 |
| 3/0 | 3×95/50KON+3x(1.5ST KÖN/1.5 UL KON) | 58 | – | 6580 | 4275 |
| 4/0 | 3×120/70KON+3x(1.5ST KÖN/1.5 UL KON) | 61 | – | 7600 | 5400 |
| 250 MCM | 3×150/70KON+3x(1.5ST KÖN/1.5 UL KON) | 65 | – | 9350 | 6750 |