(N)TMCGETMPU vs RIT-(N)TMCGETMPU Portable Trailing Cable

(N)TMCGETMPU and RIT-(N)TMCGETMPU portable mining cables both comply with VDE 0250 Part 813 and IEC 60502 standards, supporting voltage classes from 3.6/6 kV up to 18/30 kV, and Both cables use similar electrical insulation systems; however, RIT-(N)TMCGETMPU incorporates an enhanced anti-torsion construction and an integral filled jacket design, providing improved performance during continuous reeling, twisting, and high-mechanical-load applications.

  • Voltage rating6/10 kV to 14/25 kV
  • ConductorTinned copper, class 5
  • InsulationEPR
  • JacketHeavy-Duty TPU
  • Power conductors3×70 – 3×185 mm2
  • Overall diameter53.2 – 84.0 mm
  • Weight (approx.)5050 – 13200 kg/km
  • Max. conductor temperature90°C
Product overview

The RIT-(N)TMCGETMPU Portable Mining Trailing Cable is an upgraded version specifically developed for mining equipment operating under extremely high tensile loads, continuous reeling, repetitive torsion, and severe mechanical stress.

While maintaining the same electrical performance as the standard cable, the reinforced design significantly improves durability under dynamic operating conditions.

  • (N)TMCGETMPU Trailing Cable is the dedicated power cable for core large mining equipment such as underground continuous miners, longwall shearers, open-pit electric shovels and draglines, as well as Tunnel Boring Machines in tunnel projects.
  • RIT-(N)TMCGETMPU Trailing Cable is an upgraded high-strength version, targeting extreme torsion, tension and high-frequency reeling scenarios in the harshest mining environments, with longer service life and higher comprehensive safety.

Application & Features

Advantages of RIT-(N)TMCGETMPU Portable Mining Trailing Cable

The RIT-(N)TMCGETMPU Portable Mining Trailing Cable has been specifically engineered for medium-voltage power distribution in demanding mining environments where conventional trailing cables often experience premature wear. Compared with standard portable mining cables, the reinforced RIT design provides higher mechanical reliability, longer service life, and lower maintenance costs.

1. Superior Torsion Resistance

One of the most significant advantages of the RIT-(N)TMCGETMPU cable is its enhanced torsion-resistant construction. The cable incorporates an integral filled jacket design that minimizes internal conductor movement during repeated winding, unwinding, and twisting operations.

This feature makes the cable ideal for continuous cable reel systems, draglines, electric shovels, and other mobile mining equipment subjected to constant dynamic movement.

2. Exceptional Abrasion Resistance

The heavy-duty Thermoplastic Polyurethane (TPU) outer sheath offers excellent protection against:

  • Sharp rocks
  • Gravel
  • Ore fragments
  • Steel structures
  • Continuous dragging
  • Mechanical impacts

Compared with conventional rubber sheaths, TPU provides significantly improved wear resistance and extends the operational life of the cable in harsh mining environments.

3. High Mechanical Strength

The optimized cable assembly improves resistance to:

  • Tensile loads
  • Crushing forces
  • Impact damage
  • Repeated bending
  • Mechanical vibration
  • Dynamic movement

These characteristics reduce conductor fatigue and improve operational reliability during long-term mining operations.

Technical Feature

Performance Features

  • Higher torsion resistance
  • Improved tensile performance
  • Longer reeling life
  • Excellent flexibility
  • Reduced maintenance
  • Longer service intervals
  • Enhanced reliability under continuous movement

Typical Characteristics

  • Voltage Rating: 6/10 kV to 14/25 kV
  • Maximum Conductor Temperature: 90°C
  • Short Circuit Temperature: 200°C
  • Cold Flexibility: -30°C
  • Excellent abrasion resistance
  • High oil resistance
  • Superior weather resistance
  • Outstanding flexibility for trailing applications
tebaoflex RIT-(N)TMCGETMPU trailing cable
Tebaoflex-Cable-RIT-(N)TMCGETMPU

Specifications

Ordering Information of RIT-(N)TMCGETMPU Cable

Number and cross-section of power + grounding conductors Power conductor stranding Grounding/Ground check conductor stranding Nominal insulation thickness Nominal jacket thickness Approximate overall diameter Maximum conductor resistance at 20℃ Ampacity at ambient temperature 30℃ Approximate weight of cable
mm2 Nx mm Nx mm mm mm mm Ω/km A kg/km
6/10 kV
3×70+2×35+1×35 514×0.4 254×0.4/254×0.4 2.9 5.5 53.2 0.277 250 5050
3×95+2×35+1×35 684×0.4 254×0.4/254×0.4 2.9 5.5 61.0 0.210 301 6401
3×120+2×50+1×35 870×0.4 364×0.4/254×0.4 2.9 5.5 64.7 0.164 352 7067
3×185+2×70+1×35 1325×0.4 514×0.4/254×0.4 2.9 5.5 74.0 0.108 461 10300
8.7/15 kV
3×70+2×35+1×35 514×0.4 254×0.4/254×0.4 3.7 5.5 61.0 0.277 265 5300
3×95+2×35+1×35 684×0.4 254×0.4/254×0.4 3.7 5.5 66.0 0.210 319 6300
3×120+2×50+1×35 870×0.4 364×0.4/254×0.4 3.7 5.5 70.0 0.164 371 7600
3×185+2×70+1×35 1325×0.4 514×0.4/254×0.4 3.7 5.5 77.5 0.108 488 11300
14/25 kV
3×70+2×35+1×35 514×0.4 254×0.4/254×0.4 5.5 5.5 67.4 0.277 265 7200
3×95+2×35+1×35 684×0.4 254×0.4/254×0.4 5.5 5.5 73.0 0.210 319 8200
3×120+2×50+1×35 870×0.4 364×0.4/254×0.4 5.5 5.5 76.0 0.164 371 8600
3×185+2×70+1×35 1325×0.4 514×0.4/254×0.4 5.5 5.5 84.0 0.108 488 13200

Construction

RIT-(N)TMCGETMPU Cable Construction

  • 1.Conductors: Finely stranded tinned copper, flexible, class 5 in accordance with IEC 60228
  • 2.Conductor shield: Semi-conductive layer over the conductor
  • 3.Insulation: Special thermosetting Ethylene-Propylene Rubber (EPR). High electrical, mechanical and temperature properties. Quality better than type 3GI3 according to DIN VDE 0207, Part 20
  • 4. Insulation shield: Semi-conducting strippable layer
  • 5.Grounding conductor (Earth): Tinned copper conductor, flexible, finely stranded
  • 6.Ground check conductor: Annealed tin coated copper in accordance with IEC 60228. Polypropylene insulation, yellow colour
  • 7. Jacket: Thermoplastic Polyurethane (TPU) compound, for extra heavy usage, oil resistant, very highly abrasion and very highly tear resistant

(N)TMCGETMPU Cable Construction

The (N)TMCGETMPU Portable Mining Trailing Cable is manufactured for medium-voltage mining applications requiring excellent flexibility, electrical reliability, and long service life. Its construction follows internationally recognized mining cable design principles and incorporates high-quality insulating and protective materials suitable for harsh operating environments.

  • Conducltor: finely stranded tinned copper conductors calss 5 provide maximum flexibility while resisting corrosion in humid underground environments.
  • Semi-Conductive Shielding System: Extruded conductor and insulation shields provide uniform electrical stress control and improve long-term dielectric reliability.
  • Insulation: Thermosetting EPR insulation offers excellent dielectric strength, thermal stability, and mechanical flexibility under repeated bending cycles.
  • Ground Check Conductor: A dedicated insulated ground-check conductor continuously monitors earth continuity and supports safe mining operations.
  • Dual Grounding Conductors: Flexible tinned copper grounding conductors ensure effective grounding and improve electrical safety.
  • Reinforced Core Assembly: The internal cable assembly incorporates optimized fillers, compact core geometry, and an integral filled jacket design that significantly improves resistance to torsional stress.
  • Enhanced Anti-Torsion Design: One of the most important differences between RIT-(N)TMCGETMPU and the standard cable is its reinforced anti-torsion construction. This design reduces internal conductor movement during continuous winding and unwinding, extending cable service life in demanding mining environments.
  • Outer Sheath: Heavy-Duty TPU

More Details

Differences Between (N)TMCGETMPU and RIT-(N)TMCGETMPU

Structural Differences

Comparison Item (N)TMCGETMPU RIT-(N)TMCGETMPU
Reinforcement Layer Optional aramid/steel braid Standard polyester-aramid hybrid anti-torsion braid
Central Strength Member Not equipped, external reinforcement optional Integrated full-length aramid strength member (standard)
Torsion Resistance Standard ±15°/m Enhanced ±25°/m
Tensile Strength 20~30 kN 40~50 kN
Core Lay-Up Standard stranding pitch Optimized short pitch for better flexibility
Outer Sheath Standard 5GM5 rubber Modified 5GM5 with higher tear strength

Application Differences

(N)TMCGETMPU: it is a cost-effective standard mining trailing cable, suitable for general mobile mining equipment with moderate mechanical stress and intermittent movement. . The cable is applicable to working conditions with bending cycles within 10,000 times, featuring stable basic performance and competitive cost, which is the preferred choice for conventional mining power distribution

RIT-(N)TMCGETMPU: it is a premium reinforced model, focusing on extreme working conditions with continuous reeling, frequent twisting and heavy load dragging, It is the dedicated power cable for core large mining equipment such as underground continuous miners, longwall shearers, open-pit electric shovels and draglines, as well as Tunnel Boring Machines in tunnel projects.

tebaoflex-NSHTOEU-applicaiton

What's RIT-(N)TMCGETMPU Portable Mining Trailing Cable

  • RIT-(N)TMCGETMPU is a high-performance medium-voltage portable mining trailing cable with rated voltage covering 3.6/6 kV to 18/30 kV. It is specially designed for the harshest mobile mining working scenarios, especially for equipment that needs continuous reeling, frequent unreeling, long-distance dragging and severe twisting during operation.
  • Based on the mature technical platform of (N)TMCGETMPU, it realizes comprehensive reinforcement of anti-torsion, tensile, anti-abrasion and anti-impact performance through RIT exclusive structural upgrades. The cable can work stably in the temperature range from -30°C to +90°C, maintaining excellent flexibility even in low-temperature environments, and will not become hard and brittle.
  • The core design purpose of RIT-(N)TMCGETMPU is to provide continuous, safe and stable power supply for large heavy-duty mobile mining equipment. Its application scope covers underground coal mines, metal mines, open-pit mines, tunnel engineering and large quarry projects.
  • In terms of certification and compliance, the cable strictly follows VDE 0250 Part 813 and IEC 60502 standards for medium-voltage power cables. It can also be equipped with MSHA certification for the North American market and ATEX certification for explosive hazardous areas on demand. All products pass IEC 60332-1 flame retardant test, fully complying with global mainstream mining safety specifications.
  • Compared with traditional rubber-sheathed mining cables, the RIT-(N)TMCGETMPU design offers significantly improved resistance to abrasion, tearing, torsion, oil exposure, and environmental aging, making it one of the preferred cable solutions for modern mining operations where equipment reliability and reduced maintenance costs are critical.

Why Choose TEBAOFLEX RIT-(N)TMCGETMPU?

TEBAOFLEX manufactures premium mining cables designed for the world’s most demanding mining environments.

Our RIT-(N)TMCGETMPU cables provide:

  • Medium-voltage ratings from 6/10 kV to 14/25 kV
  • Premium EPR insulation
  • Heavy-duty TPU jacket
  • Superior abrasion resistance
  • Enhanced torsion resistance
  • Oil and chemical resistance
  • Flexible Class 5 tinned copper conductors
  • OEM & customized solutions
  • Global technical support

Whether powering electric shovels, draglines, continuous miners, mobile crushers, or drilling equipment, TEBAOFLEX RIT-(N)TMCGETMPU Portable Mining Trailing Cables deliver reliable performance, maximum durability, and lower total ownership costs.

Application Cases of RIT-(N)TMCGETMPU

Case 1: Underground Metal Mine – Continuous Miner

The application site is a deep underground copper mine in Chile, and the core equipment is a 6/10 kV continuous miner. The tunnel space is narrow, the cable is in a wet environment all year round, and it will generate continuous torsion of about ±20° per meter during the operation of the miner. Sharp ore particles also cause serious abrasion to the cable sheath.

The project selected RIT-(N)TMCGETMPU 6/10 kV 3×70 mm² cable. The cable runs 24 hours a day in the ambient temperature of -20°C to +40°C. Within two years of operation, there is no fault caused by torsion and abrasion. It completely eliminates unplanned shutdowns due to cable damage and improves the overall operation efficiency of the mining equipment by 15%.

Dragline-Mining-Cable Longwall-Miner-mining-cable

Case 2: Urban Tunnel Project – TBM Power Supply

This case is an urban metro tunnel construction project in Europe, using large Tunnel Boring Machine with a rated voltage of 12/20 kV. The cable laying length reaches 300 to 500 meters. During the tunneling process, the cable is continuously reeled and bears long-distance tensile load, and is often soaked by muddy water.

The construction team adopted RIT-(N)TMCGETMPU 12/20 kV 3×120 mm² cable. Its excellent tensile resistance and waterproof structure keep the insulation performance stable for a long time. The cable can withstand the maximum tensile force of 45 kN during reeling. After putting into use, the cable replacement frequency is reduced by 70%, providing a solid guarantee for the smooth progress of the tunnel project.

coal-mining-cable

FAQ

1. What equipment uses RIT-(N)TMCGETMPU cables?

Typical applications include:

  • Electric shovels
  • Draglines
  • Continuous miners
  • Mobile crushers
  • Blast-hole drills
  • Dredges
  • Track-mounted mining equipment
  • Cable reel systems
2. Why is TPU used for the outer sheath?

TPU provides outstanding resistance to abrasion, tearing, oil, impact, chemicals, UV exposure, and weathering, making it one of the preferred sheath materials for heavy-duty mining cables.

3. Is RIT-(N)TMCGETMPU suitable for underground mining?

Yes. The cable is designed for both underground and surface mining operations where continuous movement and severe mechanical stresses are present

4. Can TEBAOFLEX manufacture customized mining cables?

Yes. TEBAOFLEX provides customized conductor sizes, voltage ratings, jacket colors, grounding configurations, and OEM solutions to meet specific mining project requirements.

Request a quote

Request this cable.

Send the core configuration, length and application details.

Request a quotation

Contact directly

Talk to our cable team.


Quality Assurance

Testing at every stage in our own workshop and laboratory, from incoming copper to the packed drum.

Bare copper wire bobbins inspected before stranding at the TEBAOFLEX factory

Raw Material Inspection

Every batch of copper rod, rubber compound and reinforcing material is checked before it reaches the line.

  • Copper: conductor resistance, elongation and surface condition on incoming rod and drawn wire
  • EPR, CPE, PUR and silicone compounds: hardness, tensile strength, elongation and ageing samples from each mix
  • Suppliers and batch numbers are recorded so every drum can be traced back to its materials
Operator monitoring an extrusion line control panel in the TEBAOFLEX workshop

Manufacturing Process Control

Stranding, insulation extrusion, core assembly and sheathing run under recorded process parameters.

  • Class 5/6 stranding with lay length and tension monitored for trailing and reeling flexibility
  • Continuous-vulcanisation extrusion with wall thickness and spark tests logged on every length
  • Operators sign off each stage before the cable moves to the next machine
3.5 kV voltage withstand test station in the TEBAOFLEX laboratory

Electrical Testing

Finished lengths go through the routine tests required by the referenced VDE, ICEA, IEC or NEK standard.

  • Conductor resistance and insulation resistance on every length
  • Voltage withstand (3.5 kV and higher) and partial-discharge measurement in the shielded HV laboratory
  • Screen and pilot-core continuity checks for mining and reeling constructions
Tensile testing machine for conductor and sheath samples

Mechanical and Ageing Tests

Samples from production are tested for the duty a mining, crane or submersible cable will actually see.

  • Tensile strength and elongation of insulation and sheath before and after ageing
  • Hot-set, ozone, oil-immersion and low-temperature bending tests
  • Constant-temperature water bath for insulation resistance of submersible constructions
Single-cable vertical flame test chamber

Flame Test and Final Inspection

Before packing, the cable is checked against the order and the flame-performance requirement of its standard.

  • Single-cable vertical flame test to IEC 60332-1-2 where specified
  • Metre marking, printing, drum length and appearance inspection
  • Test report and packing list issued with every shipment

Need Pricing for This Cable?

Tell us the length, cores, cross-section and delivery country and we will reply with a quotation and datasheet.

Get A Quote
(N)TMCGETMPU vs RIT-(N)TMCGETMPU Portable Trailing CableGet A Quote