

Products
Product Categories
Heavy-duty rubber cables for mining, port cranes, submersible pumps, EV charging, elevators and marine duty. Pick a family to filter the range.
All Products
TEBAOFLEX manufactures heavy-duty rubber cables from 0.6/1 kV to 35 kV: VDE and ICEA mining trailing and reeling cables, port crane reeling and festoon cables, submersible pump cables, EV charging and automotive powertrain cables, elevator travelling cables and marine and offshore cables. Pick a family above or browse the full range below.
Looking for ground-check mining cable? Explore TEBAOFLEX Type G-GC 2000V cable for sizes, specifications and quotation enquiries.
Showing 33–48 of 93 results
-

HLR2GCB2G 0.6/1kV Shielded Silicone Automotive Powertrain Cable 25–95mm²
-

ICEA 2000V Flat&Round Type W Portable Power Mining Cable 4 0 AWG
-

LiYCY Cable: Screened PVC Data and Control Cable, 0.14 to 1.5 mm²
-

LiYY Cable: Unscreened PVC Data and Control Cable, 0.14 to 0.75 mm²
-

LS3SU Shipboard Cable, 18 AWG Shielded Triads, 600V, MIL-DTL-24643/35 Type
-

MGM 101 500V Headcap Lamp Mining Cable 2×1mm²
-

MGM 109 Type 1012/1013/1014 0.6/1kV Single Armoured Mining Cable
-

MGM 109 Type 3013 3.3kV Single Armoured Mining Power Cable
-

MGM 109 Type 3023 3.3kV Unscreened Double Armoured Mining Cable
-

MGM 109 Type 3123 3.3kV Screened Armoured Mining Power Cable
-

MGM 110 110V Armoured Telephone and Signal Mining Cable
-

MGM 111 Type 320/321 3.3kV Screened Armoured Mining Cable
-

MGM 112 Type 201/211 660/1100V Screened Armoured Mining Power Cable
-

MGM 112 Type 321 3.3kV Unscreened Armoured Mining Power Cable
-

MGM 112 Type 331 3.3kV Screened Armoured Mining Power Cable
-

MGM 112 Type 62/63/64 660/1100V Screened Armoured Mining Cable 4mm²
Product Advantages
What sets TEBAOFLEX Heavy-Duty Rubber Cable apart in service.
Heavy-Duty Rubber Sheath
CR/PCP, CPE or PUR outer sheaths resist abrasion, tearing, oil and weather on trailing, reeling and festoon duty.
Class 5 / 6 Flexible Conductors
Fine-stranded tinned copper to IEC 60228 for repeated bending, reeling and dragging behind mobile machines.
0.6/1 kV to 35 kV
Low- and medium-voltage constructions across the mining, crane, pump, marine, elevator and EV charging families.
Screened & Monitored
Semi-conductive screens, earth and pilot cores support ground-check monitoring on medium-voltage mining cables.
Flame-Retardant & LSZH Options
IEC 60332 flame-retardant and low-smoke halogen-free versions such as (N)3GHSSHCH for tunnels and underground works.
Certified & Routine-Tested
UL, cUL, VDE, CE, KTL and MA approvals; every length passes routine electrical tests in our own HV laboratory.
Technical Specifications
Capabilities across the Heavy-Duty Rubber Cable range; each product page lists the exact construction, rating and reference standard.
| Specification | Available options |
|---|---|
| Voltage range | 0.6/1 kV up to 35 kV (26/35 kV medium-voltage reeling and trailing types) |
| Conductor | Tinned or bare copper, Class 5 / Class 6 flexible stranding to IEC 60228 |
| Insulation | EPR, XLPE, silicone rubber, PVC |
| Sheath compounds | CR / PCP, CPE, PUR, LSZH; reinforced double-sheath constructions |
| Screening & elements | Copper braid, tinned copper wire and semi-conductive screens; earth, pilot and fibre-optic (LWL) elements |
| Temperature rating | -40 °C to +90 °C for EPR types; high-temperature silicone types on request |
| Fire performance | Flame-retardant to IEC 60332-1-2; low-smoke halogen-free (LSZH) versions |
| Installation duty | Trailing, reeling, festoon, shuttle-car, submersible, fixed and vertical (elevator) installation |
| Applicable standards | VDE 0250, ICEA S-75-381, IEC 60502 / 60228 / 60332, NEK 606, IEEE 1580, MT/T 818, EN 50620 / IEC 62893 |
| Testing & certification | Routine electrical, partial-discharge, mechanical, ageing and flame tests; UL, cUL, VDE, CE, KTL, MA; ISO 9001 / 14001 / 45001 |
| Cable families | Mining trailing, port crane reeling and festoon, submersible pump, EV charging, elevator travelling, marine and offshore, ROV umbilical |
| Customisation | Constructions, screens, fibre-optic elements, colours, printing and drum lengths built to specification or drawing; OEM supply |
Application Scenarios
Where Heavy-Duty Rubber Cable from TEBAOFLEX is installed.
Underground Mining & Tunnelling
Trailing, shuttle-car, LHD reeling and shield-machine cables for continuous miners, roadheaders, TBMs and underground conveyors, with LSZH options for tunnels.
02Open-Pit Mining
Type SHD-GC, G-GC, W and DLO cables for draglines, electric shovels, drills and pit distribution, built to ICEA S-75-381 with ground-check pilots.
03Port Cranes & Reeling Systems
Reeling and festoon cables for ship-to-shore, RTG and RMG cranes, spreaders and ship unloaders, including medium-voltage reeling cables with fibre-optic elements.
04Submersible Pumps
Flat and round rubber pump cables for deep-well, dewatering and drainage pumps in continuous immersion.
05EV Charging
Charging cables to EN 50620 / IEC 62893 for AC and DC chargers, with oil-, UV- and abrasion-resistant sheaths.
06Elevators & Vertical Transport
Flat and round travelling cables for lifts, hoists and vertical conveyors that run through millions of bending cycles.
How to Choose Heavy-Duty Rubber Cable
Four decisions specify the right cable the first time; send them with your RFQ and our engineers confirm the type designation.
Voltage Rating & Standard
Start from the rated voltage (0.6/1 kV, 3.6/6 kV, 6/10 kV, 8.7/15 kV, 26/35 kV) and the standard the site specifies: VDE, ICEA, IEC, NEK or MT/T.
Movement & Installation
Trailing behind a machine, wound on a reel, hung on a festoon, submerged or fixed: the duty sets the conductor class, reinforcement and sheath.
Conductor, Screen & Sheath
Choose cores and cross-section for the load and route, then screens, pilot or fibre-optic elements and the sheath compound the environment needs.
Environment & Approvals
Temperature range, oil, water, UV, flame performance and required approvals (UL, VDE, CE, KTL, MA) close the specification.
Industry Solutions
Cable packages engineered around the application, not just the cable.
Global Projects
Recent deliveries from the TEBAOFLEX project team.
Standards & Certifications
ISO 9001 quality management for cable production; ISO 14001 and ISO 45001 for sales and related management. UL and cUL (flexible cord), VDE (EN 50525-2-21), Korea KC, China MA and US MSHA approvals cover the certified types; CE is a third-party verification of conformity (VoC).




Manufacturing Process
From compound to shipment, the production steps and routine tests behind each cable length.
- 1
Compound preparation
EPR, CPE, PUR and silicone compounds are mixed and tested for hardness, tensile strength and elongation before use.
- 2
Conductor stranding
Tinned or bare copper is bunched and rope-stranded to Class 5/6 flexibility for trailing and reeling duty.
- 3
Insulation extrusion
Cores are extruded and continuously vulcanised; wall thickness and spark tests are recorded on every length.
- 4
Core assembly and screening
Cores, earth conductors, pilot and fibre-optic elements are laid up with the fillers and screens the type designation requires.
- 5
Inner and outer sheathing
Reinforced double-sheath constructions are extruded and cured for abrasion, oil and tear resistance.
- 6
Routine electrical tests
Conductor resistance, voltage withstand and insulation resistance tests at the levels set by the referenced standard.
- 7
Mechanical and ageing tests
Bending, tensile, hot-set, ozone and flame tests according to the referenced standard.
- 8
Marking, packing and shipment
Metre marking, drum packing and documentation for worldwide project delivery.
Cable Manufacturing Quality Control
Five-stage quality assurance from incoming copper to the packed drum.
- 01
Raw Material Inspection
Every batch of copper rod, rubber compound and reinforcing material is checked before it reaches the line.
- Copper: conductor resistance, elongation and surface condition on incoming rod and drawn wire
- EPR, CPE, PUR and silicone compounds: hardness, tensile strength, elongation and ageing samples from each mix
- 02
Manufacturing Process Control
Stranding, insulation extrusion, core assembly and sheathing run under recorded process parameters.
- Class 5/6 stranding with lay length and tension monitored for trailing and reeling flexibility
- Continuous-vulcanisation extrusion with wall thickness and spark tests logged on every length
- Operators sign off each stage before the cable moves to the next machine
- 03
Electrical Testing
Finished lengths go through the routine tests required by the referenced VDE, ICEA, IEC or NEK standard.
- Conductor resistance and insulation resistance on every length
- Voltage withstand test at the level set by the referenced standard
- Screen and pilot-core continuity checks for mining and reeling constructions
- 04
Mechanical and Ageing Tests
Samples from production are tested for the duty a mining, crane or submersible cable will actually see.
- Tensile strength and elongation of insulation and sheath before and after ageing
- Hot-set, ozone, oil-immersion and low-temperature bending tests
- Constant-temperature water bath for insulation resistance of submersible constructions
- 05
Flame Test and Final Inspection
Before packing, the cable is checked against the order and the flame-performance requirement of its standard.
- Single-cable vertical flame test to IEC 60332-1-2 where specified
- Metre marking, printing, drum length and appearance inspection
- Packing list with every shipment; test documents for the order confirmed at quotation
Factory & Workshop Gallery
TEBAOFLEX CABLE, No.77 Wusongbang Road, Taicang, Suzhou.




Related Articles
Selection and application guides from the TEBAOFLEX engineering team.

Oil Resistant Cable: PR I vs PR II
PR I is a 96-hour oil immersion, PR II is 1,440 hours with a higher pass mark. What the two UL ratings prove, and how to specify oil duty.
Read more
Abrasion-Resistant Mining Cable for Mobile Equipment
Why mining cable jackets wear out on mobile equipment, how CPE, TPU/PUR and PVC compare, and how to match the jacket to trailing or reeling duty.
Read more
Armoured and Static Mining Cable: Fixed Distribution Routes
Armoured mining cable suits static routes, not trailing duty, and its armour is pliable not rigid SWA. Compare fixed routes, pilot cores and standards.
Read moreFrequently Asked Questions
Quick answers about Heavy-Duty Rubber Cable from our engineers.
01What cables does TEBAOFLEX manufacture?
0.6/1 kV to 35 kV heavy-duty rubber cables: VDE and ICEA mining trailing and reeling cables, port crane reeling and festoon cables, submersible pump cables, marine and offshore cables (NEK 606, IEEE 1580 Type P), elevator travelling cables, EV charging cables, silicone and high-temperature cables, ROV umbilicals and custom constructions, more than 1,500 cable types in total.
02Which standards do your cables comply with?
Depending on the family: VDE 0250 / DIN VDE designations, ICEA S-75-381 (SHD-GC, G-GC, W, MP-GC), IEC 60502, IEC 60228, IEC 60332, NEK 606, IEEE 1580, MT/T 818 (MA-certified mining cables) and EN 50620 / IEC 62893 for EV charging cables.
03Can you manufacture customised cables?
Yes. Constructions, conductor classes, screens, fibre-optic elements, sheath compounds, colours, printing and drum lengths can all be built to your specification or drawing.
04How do you ensure product quality?
Production runs under an ISO 9001 quality management system. Incoming copper and compounds are inspected, process parameters are recorded at each machine, and finished lengths pass the routine electrical tests required by the referenced standard. Ask for the test documents you need with your quotation.
05How do I request a quotation?
Use the inquiry form, WhatsApp or email. Our engineers check the parameters within 24 hours, confirm materials and construction, and send a formal price and lead-time offer.
06What information should I provide for a quote?
Working environment, rated voltage, number of cores and cross-section, standard or type designation, required length, bending frequency or reeling duty, temperature range and special functions such as oil resistance, flame performance or fibre-optic elements. Attach drawings if available.
Why Choose Us
A special-cable manufacturer in Taicang, Suzhou, making heavy-duty and special cables since 2014.
Certified Quality
UL and cUL, VDE, Korea KC, China MA and US MSHA approvals for the certified types, CE verification of conformity, and ISO 9001 quality management.
200+ Sets of Equipment
More than 200 sets of advanced production and test equipment at home and abroad, from compounding to final electrical testing.
15 Senior Cable Engineers
Constructions engineered to VDE, ICEA, IEC and NEK 606 standards and checked against the real duty cycle of your equipment.
1,500+ Cable Types
0.6/1 kV to 35 kV heavy-duty rubber cables, reeling and festoon crane cables, submersible, marine, ROV and high-temperature cables.
Custom Cable Design
Special constructions, fibre-optic elements, colours, printing and lengths built to the specification of your project.
Worldwide Project Supply
Cables working in tunnel engineering, marine and offshore equipment, mining, petrochemical, steel and urban construction projects around the world.
Can’t Find What You Need?
Send us the equipment, voltage, cores and operating conditions and our engineers will propose a cable construction and quotation.






