(N)3GHSSHCH LSZH Tunnelling & Underground Mining Cable
Application: (N)3GHSSHCH features a low-smoke zero halogen (LSZH) inner and outer sheath for use in environments where there is a potential fire hazard. The cable is designed to withstand the stresses of underground and mining environments, including chemical and climatic stresses. e.g.high-voltage transformers in mining and tunnelling.
- Voltage3.6/6kV, 6/10kV, 8.7/15kV, 12/20kV
- ConductorClass 5 Flexible Stranded Copper
- Insulation3GI3 type EPR compound
- Inner / outer sheathLSZH (Low Smoke Zero Halogen)
- ArmourSteel Wire Braid over the Second Inner Sheath
- Cores3 phase + 3 earth + 3 control
- Overall diameter47.0 – 82.0 mm
- Weight (approx.)3600 – 12400 kg/km
TEBAOFLEX CABLE is customer-oriented in the design and manufacture of cables and products, providing (N)3GHSSHCH cable customized product services, Suitability: For use in the Mining industry for tunnelling and underground applications requiring low smoke and zero halogen properties (LSZH).
All performance requirements of the customer’s heva-duty rubber cable working application, and we are committed to providing high-quality services and products to customers at competitive prices at all levels.
Cores: 3 phase + 3 earth + 3 control conductor configuration. Steel Wire Braid (SWB) over the second inner sheath means these cables are designed to withstand mechanical, chemical and climate stresses.
Application & Features
Selection overview
Tebaoflex (N)3GHSSHCH Cable Design Feature
- Voltage RatingThe (N)3GHSSHCH is manufactured to VDE0250 Standard for Voltage Ratings (Uo/U) of 3.6/6kv, 6/10kV or 8.7/15kV, 12/20kV, and they are designed to operate in ambient temperatures of -40oC to +80oC when fixed and +5oC to +80oC when flexed
- Specification(N)3GHSSHCH designed for use in the Mining industry for tunnelling and underground applications, the (N)3GHSSHCH cable offers a flexible power supply to Medium Voltage (MV) equipment with a black Low Smoke Zero Halogen (LSZH) inner (x2) and outer sheathing.
- SuitabilityAs feeder cable for power supply of shiftable MV equipment, e.g. compressure resistant transformers, for underground mining applications as well as for tunnel sites. For use in the Mining industry for tunnelling and underground applications requiring low smoke and zero halogen properties (LSZH).


Specifications
Technical data
(N)3GHSSHCH LSZH Tunnelling Mining Cable Parameter Data
| Cross Section | Overall Diameter Mln-Max | Conductor Resistance At 20 °C | Approxlmate welght |
|---|---|---|---|
| (mm2) | (mm) | (Ω/km) | (kg/km) |
| 3,6/6 kV (N)3GHSSHCH LSZH Mining Cable | |||
| 3×25 + 3×16/3E + 3×2,5st + .L | 47.0 – 51.0 | 0.78 | 3600 |
| 3×70 + 3×35/3E + 3×2,5st + .L | 56.1 – 61.2 | 0.272 | 5900 |
| 3×95 + 3X50/3E + 3×2,5st + .L | 60.3 – 66.2 | 0.206 | 5900 |
| 3×120 + 3×70/3E + 3×2,5st + .L | 63.8 – 70.2 | 0.161 | 8620 |
| 3×150 + 3×70/3E + 3×2,5st + .L | 66.0 – 72.0 | 0.129 | 9860 |
| 3×185 + 3×95/3E + 3×2,5st + .L | 70.0 – 74.0 | 0.106 | 11300 |
| 6/10 kV | |||
| 3×25 + 3×16/3E + 3×2,5st + .L | 54.0 – 57.0 | 0.78 | 4200 |
| 3×35 + 3×16/3E + 3×2,5st + .L | 57.1 – 60.2 | 0.554 | 4650 |
| 3×50 + 3×25/3E + 3×2,5st + .L | 60.4 – 63.6 | 0.386 | 5380 |
| 3×70 + 3×35/3E + 3×2,5st + .L | 65.2 – 68.8 | 0.272 | 6450 |
| 3×95 + 3X50/3E + 3×2,5st + .L | 68.0 – 71.9 | 0.206 | 7700 |
| 3×120 + 3×70/3E + 3×2,5st + .L | 70.1 – 76.1 | 0.161 | 9260 |
| 3×150 + 3×70/3E + 3×2,5st + .L | 73.0 – 78.0 | 0.129 | 10840 |
| 3×185 + 3×95/3E + 3×2,5st + .L | 74.0 – 79.2 | 0.106 | 12400 |
| 8,7/15 kV (N)3GHSSHCH LSZH Mining Cable | |||
| 3×25 + 3×16/3E + 3×2,5st + .L | 54.2 – 58.0 | 0.78 | 4530 |
| 3×35 + 3×16/3E + 3×2,5st + .L | 55.0 – 60.0 | 0.554 | 5100 |
| 3×50 + 3×25/3E + 3×2,5st + .L | 58.0 – 61.0 | 0.386 | 5840 |
| 3×70 + 3×35/3E + 3×2,5st + .L | 65.2 – 67.0 | 0.272 | 7840 |
| 3×95 + 3X50/3E + 3×2,5st + .L | 66.0 – 69.0 | 0.206 | 9120 |
| 12/20 kV (N)3GHSSHCH LSZH Mining Cable | |||
| 3×25 + 3×16/3E + 3×2,5st + .L | 54.4 – 58.2 | 0.78 | 4920 |
| 3×35 + 3×16/3E + 3×2,5st + .L | 55.4 – 60.0 | 0.554 | 5400 |
| 3×50 + 3×25/3E + 3×2,5st + .L | 58.0 – 61.0 | 0.386 | 6200 |
| 3×70 + 3×35/3E + 3×2,5st + .L | 65.2 – 67.0 | 0.272 | 7320 |
| 3×95 + 3X50/3E + 3×2,5st + .L | 66.0 – 69.0 | 0.206 | 8630 |
| 3×120 + 3×70/3E + 3×2,5st + .L | 68.7 – 74.0 | 0.161 | 9260 |
| 3×150 + 3×70/3E + 3×2,5st + .L | 74.0 – 78.0 | 0.129 | 10460 |
| 3×185 + 3×95/3E + 3×2,5st + .L | 78.0 – 82.0 | 0.106 | 11870 |
Difference voltage of (N)3GHSSHCH Cable Structure

| VOLTAGE | (N)3GHSSHCH – 3.6/6kV and 6/10kV Cable | (N)3GHSSHCH – 8.7/15kV and 12/20kV Cable |
|---|---|---|
| 3.6/6kV & 6/10kV | 8.7/15kV & 12/20kV | |
| PHASE CONDUCTOR | Class 5 Flexible Stranded Copper | |
| INSULATION | Rubber Compound | |
| SEMI-CONDUCTIVE LAYERS | Semi-Conductive Tape over the Conductor and Inner and Outer Semi-Conductive Rubber Layer on the Insulation | |
| PROTECTIVE EARTH CONDUCTOR | Individual Copper Wire Screen | |
| CONTROL CONDUCTOR | Class 5 Flexible Stranded Tinned Copper | |
| CENTRAL FILLER | Rubber Compound on a Textile Polyester Support | |
| INNER SHEATH | LSZH (Low Smoke Zero Halogen) | |
| MONITORING CONDUCTOR | Copper Wire Screen over the First Inner Sheath | |
| INNER SHEATH 2 | LSZH (Low Smoke Zero Halogen) | |
| ARMOUR | Steel Wire Braid over the Second Inner Sheath | |
| OUTER SHEATH | LSZH (Low Smoke Zero Halogen) | |
Operation Characteristics
| Rated Voltage | 3,6/6 kV | 6/10 kV | 8,7/15 kV | 2/20 kV | 18/30 kV |
|---|---|---|---|---|---|
| AC Test Voltage | 11 kV | 17 kV | 24 kV | 29 kV | 43 kV |
| Max. Permissible Operating Voltage AC | 4,2/7,2 kV | 6,9/12 kV | 10,4/18 kV | 13,9/24 kV | 20,8/36 kV |
| Max. Permissible Operating Voltage DC | 5,4/10,8 kV | 9/18 kV | 13,5/27 kV | 18/36 kV | 27/54 kV |
- Min. Bending Radius:
- Current Carrying Capacity: Acc. to DIN VDE 0298 part 3
- Working Temperature: According to DIN VDE 0298, Part 4
Fixed: -40ºC … +80ºC
Mobile: +5ºC … +80ºC - Max. Tensile Load of cable: 15 N/mm²
- Max. Torsion: 25º/m
- Travel Speed: max. 30m/min
- Minimum distance for change of direction: 20 X D
Standards & References
Applicable standards
- Voltage ratingVDE0250 Standard
- ConductorsFlexible electrolytic copper wire acc. to DIN VDE 0295 – Class 5
- Core identificationNatural coloring, design acc. to DIN VDE 0250 Part.1
- Current carrying capacityAcc. to DIN VDE 0298 part 3
- Working temperatureAccording to DIN VDE 0298, Part 4
Construction
Material and build-up
LSZH (N)3GHSSHCH Tunnelling & underground Mining Cable Construction
Voltage: 3.6/6kV, 6/10kV, 8.7/15kV, 12/20kV
- Conductors: Flexible electrolytic copper wire acc. to DIN VDE 0295 – Class 5
- Insulation Main Cores: 3GI3 type EPR compound
- Pilot Control Cores: 3GI3 type EPR compound
- Protective Conductor: Made of plain copper wires or copper wire braiding laid-up concentrically around each main core
- Electrical Field: Extruded inner and outer rubber semiconductive layer For
- Control: 3,6/6 kV cables outer semiconductive layer only
- Core Identification Main Cores: Natural coloring, design acc. to DIN VDE 0250 Part.1
- Pilot Cores: Black colored and number coded
- Lay Up: Three main conductors laid-up with three pilot control cores in the outer interstice Protective cores are concentrically wrapped over insulation of power cores
- Inner Sheath: Special Halogen free and flame retardant HFFR compound
- Monitoring: Semiconductive tape + overall concentric lay of copper wires and
- Conductor: syntetic tape over wires
- Inner Sheath: Special Halogen free and flame retardant HFFR compound
- Armour: Galvanized steel wire braiding, coverage minimum 75 %
- Outer Sheath: Special Halogen free and flame retardant HFFR compound
- Color: Red or Black
More Details
Comparison and references
(N)3GHSSHCH Tunnelling Underground Mining Cable Installation Instructions

✔ Firstly, Before installation, inspect (N)3GHSSHCH Cable for damage and verify specifications match operating requirements.
- Avoid dragging, sharp friction and excessive bending;
- follow the specified minimum bend radius.
- Keep cables away from high-temperature sources and corrosive substances.
✔ Secondly, during laying, ensure proper tension to prevent overstretching the steel wire braid armor.
- For underground and mobile use, fix cables securely with dedicated fixtures.
- Terminate cores strictly per electrical standards, guaranteeing tight connections and good insulation.
✔ Lastly, after installation, conduct insulation and continuity tests.
Do not operate the cable until all inspections pass. Wear protective gear during work and comply with local electrical safety regulations at all times.
Request this cable.
Send the core configuration, length and application details.
Quality Assurance
Testing at every stage in our own workshop and laboratory, from incoming copper to the packed drum.

Raw Material Inspection
Every batch of copper rod, rubber compound and reinforcing material is checked before it reaches the line.
- Copper: conductor resistance, elongation and surface condition on incoming rod and drawn wire
- EPR, CPE, PUR and silicone compounds: hardness, tensile strength, elongation and ageing samples from each mix
- Suppliers and batch numbers are recorded so every drum can be traced back to its materials

Manufacturing Process Control
Stranding, insulation extrusion, core assembly and sheathing run under recorded process parameters.
- Class 5/6 stranding with lay length and tension monitored for trailing and reeling flexibility
- Continuous-vulcanisation extrusion with wall thickness and spark tests logged on every length
- Operators sign off each stage before the cable moves to the next machine

Electrical Testing
Finished lengths go through the routine tests required by the referenced VDE, ICEA, IEC or NEK standard.
- Conductor resistance and insulation resistance on every length
- Voltage withstand (3.5 kV and higher) and partial-discharge measurement in the shielded HV laboratory
- Screen and pilot-core continuity checks for mining and reeling constructions

Mechanical and Ageing Tests
Samples from production are tested for the duty a mining, crane or submersible cable will actually see.
- Tensile strength and elongation of insulation and sheath before and after ageing
- Hot-set, ozone, oil-immersion and low-temperature bending tests
- Constant-temperature water bath for insulation resistance of submersible constructions

Flame Test and Final Inspection
Before packing, the cable is checked against the order and the flame-performance requirement of its standard.
- Single-cable vertical flame test to IEC 60332-1-2 where specified
- Metre marking, printing, drum length and appearance inspection
- Test report and packing list issued with every shipment
Need Pricing for This Cable?
Tell us the length, cores, cross-section and delivery country and we will reply with a quotation and datasheet.